Title
Installing the VESPA H− Ion Source Test Stand at RAL
Contributors
SR Lawrie (STFC Rutherford Appleton Lab.)
,
DC Faircloth (STFC Rutherford Appleton Lab.)
,
AP Letchford (STFC Rutherford Appleton Lab.)
,
M Perkins (STFC Rutherford Appleton Lab.)
,
M Whitehead (STFC Rutherford Appleton Lab.)
,
T Wood (STFC Rutherford Appleton Lab.)
Abstract
A Penning-type negative hydrogen (H) ion source has been used reliably on the ISIS pulsed spallation neutron and muon facility at the Rutherford Appleton Laboratory (RAL) in the UK for almost 30 years. However a detailed study of the ion source plasma and extraction has never been undertaken. If these properties were known, the beam emittance and losses due to collimation could be reduced, and the lifetime increased. This paper summarises the progress made on installing a Vessel for Extraction and Source Plasma Analyses (VESPA) to fill the knowledge gap.
Organisation
ISIS
,
ISIS-ACCEL
,
STFC
Keywords
Funding Information
Related Research Object(s):
Licence Information:
Language
English (EN)
Type
Details
URI(s)
Local file(s)
Year
Paper In Conference Proceedings
In 5th International Particle Accelerator Conference (IPAC14), Dresden, Germany, 15-20 Jun 2014, (2014): 614-616.
http://accelconf.…/papers/mopri015.pdf
2014
Showing record 1 of 1
Recent Additions
Browse Organisations
Browse Journals/Series
Login to add & manage publications and access information for OA publishing
Username:
Password:
Useful Links
Chadwick & RAL Libraries
SHERPA FACT
SHERPA RoMEO
SHERPA JULIET
Journal Checker Tool
Google Scholar