ePubs

The open archive for STFC research publications

Full Record Details

Persistent URL http://purl.org/net/epubs/work/56154
Record Status Checked
Record Id 56154
Title COLDDIAG: A Cold Vacuum Chamber for Diagnostics
Contributors
Abstract One of the still open issues for the development of superconducting insertion devices is the understanding of the heat load induced by the beam passage. With the aim of measuring the beam heat load to a cold bore and in order to gain a deeper understanding in the beam heat load mechanisms, a cold vacuum chamber for diagnostics is under construction. We plan to have access with the same set-up to a number of different diagnostics, so we are implementing: i) retarding field analysers to measure the electron flux, ii) temperature sensors to measure the total heat load, iii) pressure gauges, iv) and mass spectrometers to measure the gas content. The inner vacuum chamber will be removable in order to test different geometries and materials. COLDDIAG is built to fit in a short straight section at ANKA, but we are proposing its installation in different synchrotron light sources with different energies and beam characteristics. A first installation in DIAMOND is planned in June 2011. Here we describe the technical design report of this device and the planned measurements with beam.
Organisation ASTeC , ASTeC-MaRS , STFC
Keywords Physics , Superconductivity , Wakefields , Insertion Devices
Funding Information
Related Research Object(s):
Licence Information:
Language English (EN)
Type Details URI(s) Local file(s) Year
Journal Article IEEE Trans Appl Supercond 21, no. 3: 2300-2303. doi:10.1109/TASC.2010.2096176